Single Wythe Reinforced Walls Deerfield Beach FL

Traditional masonry walls were relatively thick compared to their height in Deerfield Beach. The introduction of reinforced masonry design has now created taller, slender single wythe masonry walls.

Woodcraft - Pompano Beach, FL
954-785-6321
Pompano Marketplace
Pompano Beach, FL
The Home Depot
(954)427-0028
60 SW 12th Ave
Deerfield Beach, FL
Sample Road Hardware, Inc
(954) 942-3961
1601 E Sample Rd
Pompano Beach, FL
TRA REPAIR SHOP
762 NE 42ND STREET POMPANO BEACH, FL, 33064
Pompano Beach, FL
Kmart 3317 / Cross Merch
(561) 392-8665
1401 W Palmetto Park Rd
Boca Raton, FL
Constantine's Wood Center of Florida, Inc.
954 561 1716
1040 E. Oakland Park Blvd.
Ft. Lauderdale, FL
The Home Depot
(954)978-6100
1151 NW Copans Rd
Pompano Beach, FL
Kmart 3398 / Cross Merch
(954) 782-8822
2421 N Federal Hwy
Pompano Beach, FL
BUILDERS CHOICE USA
2700 N POWERLINE ROAD POMPANO BEACH, FL, 33064
Pompano Beach, FL
The Home Depot
(954)971-0643
4450 N State Rd 7
Coconut Creek, FL
Data Provided by:
 
Provided By:

Single Wythe Reinforced Walls

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2006

By Walter A. Laska

Until recently, traditional masonry walls were relatively thick compared to their height. The introduction of reinforced masonry design has now created taller, slender single wythe masonry walls. The ability to construct thinner and taller walls results in initial cost savings, reduces space, and permits increased vertical clearance.

Reinforced single wythe masonry construction may require a connection in which the wall completely bypasses the steel joists. For this condition, an angle with sufficiently designed bearing capacity can be solidly grouted into a bond beam. This arrangement creates a ledger for the joist to bear on and connect to. The amount of required joist bearing should be determined by the applicable code. This type of connection results in an eccentrically loaded wall.

A structural analysis of the wall should be made to determine masonry reinforcement requirements. Ledger angles also can be bolted into the bond beam with expansion anchors after the masonry wall has been erected.

The ledger angle should be cut into sections and delivered to the site before masonry construction begins. Long sections of angles are difficult to install. Providing workable sections at the appropriate time assures proper angle embedment.

The means of joist attachment to the ledger angle should be determined by the amount of movement experienced by the joist.

Click here to read full article from Masonry Construction