Single Wythe Reinforced Walls Hollywood FL

Traditional masonry walls were relatively thick compared to their height in Hollywood. The introduction of reinforced masonry design has now created taller, slender single wythe masonry walls.

Constantine's Wood Center of Florida, Inc.
954 561 1716
1040 E. Oakland Park Blvd.
Ft. Lauderdale, FL
Woodcraft - Pompano Beach, FL
954-785-6321
Pompano Marketplace
Pompano Beach, FL
Hardware City Inc.
(954) 432-5854
1100 N University Dr, 1 block north of Johnson St. on University Dr.
Pembroke Pines, FL
The Home Depot
(954)437-2902
11001 Pines Blvd
Pembroke Pines, FL
NATIONAL TOOL SUPPLY- Hollywood
(954) 963-7222
5725 Hallandale Beach Blvd Hollywood, FL, 33023
Hollywood, FL
Foreverwood, Inc.
305-635-9222
PO Box 420158
Miami, FL
LOWE'S OF PEMBROKE PINES, FL
954 624-1900
130 NORTH UNIVERSITY DRIVE PEMBROKE PINES, FL, 33024
Pembroke Pines, FL
Lowe's
(954) 624-1900
130 North University Drive
Pembroke Pines, FL
The Home Depot
(954)961-1761
1951 South S R #7
Hollywood, FL
Contractors Equipment & Supplies
954-587-9433
4450 SW 61st Ave Unit 1 Davie, FL, 33314
Davie, FL
Data Provided by:
 
Provided By:

Single Wythe Reinforced Walls

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 2006

By Walter A. Laska

Until recently, traditional masonry walls were relatively thick compared to their height. The introduction of reinforced masonry design has now created taller, slender single wythe masonry walls. The ability to construct thinner and taller walls results in initial cost savings, reduces space, and permits increased vertical clearance.

Reinforced single wythe masonry construction may require a connection in which the wall completely bypasses the steel joists. For this condition, an angle with sufficiently designed bearing capacity can be solidly grouted into a bond beam. This arrangement creates a ledger for the joist to bear on and connect to. The amount of required joist bearing should be determined by the applicable code. This type of connection results in an eccentrically loaded wall.

A structural analysis of the wall should be made to determine masonry reinforcement requirements. Ledger angles also can be bolted into the bond beam with expansion anchors after the masonry wall has been erected.

The ledger angle should be cut into sections and delivered to the site before masonry construction begins. Long sections of angles are difficult to install. Providing workable sections at the appropriate time assures proper angle embedment.

The means of joist attachment to the ledger angle should be determined by the amount of movement experienced by the joist.

Click here to read full article from Masonry Construction